Carrier 58DFA 22SI Gas Furnace Owners Manual

Product Specification
CategoriesCarrier HVAC Manuals
Document TypeHeating, Ventilating and Air Conditioning Manual Free Download. HAVC Operator's Instruction Manual.
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 8 pages
LanguageEnglish
Product BrandCarrier. Support Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays , Heating, Ventilating and Air Conditioning - HVAC
Document File TypePDF
Publishercorp.carrier.com
Wikipedia's PageCarrier Corporation
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Heat Exchanger Cell Replacement Kit Cancels: IIK 373L-35-19 IIK 373L-35-20 11-98 Installation Instructions Part No. 310203-752 NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. INTRODUCTION This instruction covers the installation of the heat exchanger cell kit Part No. 310203-752 in models 330AAV, 330JAV, 331AAV, 331JAV, 333BAV, 333JAV, 373LAV, 376CAV, 383KAV, 393AAV, 394HAD, 395CAV, 396HAD, 480BAV, 481BAV, 58DFA, 58DHC, 58DXT, 58GFA, 58PAP, 58PAV, 58RAP, 58RAV, 58SSC, 58TMA, 58TUA, 58UHV, 58UXT, 58UXV, 58WAV, 58YAV, 58ZAV, GA1AAD, GA2AAD, GB1AAV, GB3AAV, PG8DAA, and PG8UAA Gas Furnaces.

A releasing agent (PAM cooking spray or equivalent, must not contain corn or canola oil, aromatic or halogenated hydrocarbons or inadequate seal may occur.) and RTV sealant (G.E. 162 or Dow-Corning 738) are needed before starting installation. DO NOT substitute any other type of RTV sealant. SAFETY CONSIDERATIONS Installing and servicing heating equipment can be hazardous due to gas and electrical components. Only trained personnel should install or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning coils, or cleaning and replacing filters. All other operations should be performed by trained service personnel. When working on heating equipment, observe precautions in the literature, on tags, and on labels attached to the unit. Recognize safety information. This is the safety-alert symbol. When you see this symbol on the furnace and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. Follow all safety codes. Wear safety glasses and work gloves. Have a fire extinguisher available. DESCRIPTION AND USAGE The heat exchanger cell replacement kit can be utilized to restore units having heat exchanger cells that require repair. This heat exchanger cell replacement kit contains the following items: Heat exchanger cell Fiberglass gasket Screw Installation Instructions INSTALLATION Step 1–Remove Heat Exchanger Assembly 1. Turn off gas and electrical supplies to unit. 2. Remove blower and control access doors. 3. Disconnect and remove vent pipe. 4. On hot surface ignition models: a. Unplug control box connectors from blower deck. b. Unplug inducer motor. c. Disconnect wires from pressure switch, draft safeguard switch, and primary limit switch. d. Remove wires from retainer clip on casing side. NOTE: On hot surface ignition models, it is not necessary to disconnect wires from gas valve, limit over temperature switch, hot surface ignitor, or flame sensor. 5. On continuous-pilot models, disconnect all gas control compartment wiring and carefully feed wires down through the blower deck into the blower compartment. 6. Remove burner control assembly mounting screws and remove assembly from furnace.

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website