Carrier 58DFA 5SI Gas Furnace Owners Manual

Product Specification
CategoriesCarrier HVAC Manuals
Document TypeHeating, Ventilating and Air Conditioning Manual Free Download. HAVC Operator's Instruction Manual.
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 2 pages
LanguageEnglish
Product BrandCarrier. Support Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays , Heating, Ventilating and Air Conditioning - HVAC
Document File TypePDF
Publishercorp.carrier.com
Wikipedia's PageCarrier Corporation
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Inducer Motor Replacement Kit Cancels: New IIK 373L-55-2 4-15-92 Installation Instructions Part No. 318984-751 NOTE: Read the entire instruction manual before starting the installation. INTRODUCTION This instruction covers the installation of the inducer motor mount kit in models 373LAD/LAV, 376AAW/BAW/CAV, 383KAD/KAV, 394HAD, 395AAW/BAW/CAV, 396HAD, 58DHB/DHC, 58DFA/GFA, 58RAP/RAV, 58SC/SSB/SSC, GA1AAD, and GA2AAD Gas Furnaces.

SAFETY CONSIDERATIONS Installing and servicing heating equipment can be hazardous due to gas and electrical components. Only trained personnel should install or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning coils or cleaning and replacing filters. All other operations should be performed by trained service personnel. When working on heating equipment, observe precautions in the literature and on tags and labels attached to the unit. Follow all safety codes. Wear safety glasses and work gloves. Have a fire extinguisher available. DESCRIPTION AND USAGE The inducer motor replacement kit can be utilized for repairs (or upgrades) to the inducer motor assembly on ONLY the models listed in Table 1. The inducer motor replacement kit contains the following items: Inducer Motor Assembly Harness Adapter (Molex) Harness Adapter (AMP) Installation Instruction INSTALLATION Step 1–Remove Inducer Motor Assembly 1. Set room thermostat to OFF and allow system to complete any blower off delay. 2. Turn OFF gas and electrical supplies to unit. 3. Remove blower and control access doors. 4. Unplug inducer motor. 5. Remove 3 assembly mounting screws and remove inducer motor assembly (motor, wheel, and mount) from inducer housing–be careful not to damage inducer wheel during removal. 6. Measure location of wheel to motor support to use when reassembling. Using an allen wrench, loosen inducer wheel setscrew and remove wheel from motor shaft. (See Fig. 1.) NOTE: If it is difficult to remove the wheel, lightly sand any scale or rust buildup from end of motor shaft. Apply a small amount of penetrating oil to shaft and hub. Tap lightly on hub only; (1) (1) (1) (1) do not tap or pry on any other areas of wheel. If the wheel cannot be removed without damage, a replacement wheel is required. 7. Remove 3 motor grommet screws securing motor plate to motor support. 8. Remove 2 screws securing motor to motor plate. Step 2–Reassembly 1. Using original screws, attach new motor/fan assembly provided in kit to motor plate. 2. Using original screws, attach motor support to motor plate through 3 grommets. If there was a shaft seal between the plate and support, be certain it is moved to the new assembly. Tighten screws firmly, but avoid stripping.

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website