Categories | Carrier HVAC Manuals |
---|---|
Document Type | Heating, Ventilating and Air Conditioning Manual Free Download. HAVC Operator's Instruction Manual. |
Tags | Carrier 58DXT |
Download File |
|
Language | English |
Product Brand | Carrier. Support Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays , Heating, Ventilating and Air Conditioning - HVAC |
Document File Type | |
Publisher | corp.carrier.com |
Wikipedia's Page | Carrier Corporation |
Copyright | Attribution Non-commercial |
Door Clip for Upflow/Horizontal 2-Speed Non-Condensing Furnaces Cancels: New IIK 330J-60-2 4-97 Installation Instructions Part No. 324097-701 INTRODUCTION This furnace door clip permits 2-speed, non-condensing furnaces to be used in the horizontal position. The door clip must be used when the furnace is used in the horizontal position to ensure the upper/combustion/louvered door remains in place during operation.
Step 1–Installing Door Clip on Horizontal Furnaces 1. Locate plastic bag containing kit attached to literature assembly. 2. Remove upper top plate screw after furnace is installed in horizontal position. (See Fig. 1 or 2.) 3. Position nylon grommet (large face toward screw head) on screw removed from top plate. 4. Insert screw and grommet in door clip hole as shown in Fig. 1 or 2. 5. Attach door clip and screw to top plate. 6. Instruct owner/user to rotate clip for door removal. Do not operate the furnace in the horizontal position without this door clip in place and position such to retain the door in place. Failure to follow this CAUTION could result in nuisance interruptions of furnace operation due to blower door switch not being closed. This kit contains the following items: Table 1–Contents DESCRIPTION Door Clip Nylon Grommet Installation Instructions PART NO. 324095-401 324096-401 IIK 330J-60-2/ 58DXT-2SI QUANTITY GROMMET DOOR CLIP EXISTING FURNACE CASING SCREW EXISTING FURNACE CASING SCREW GROMMET DOOR CLIP TOP PLATE A97090 TOP PLATE A97089 Fig. 1–Two-Speed Furnace in Horizontal Right Orientation Fig. 2–Two-Speed Furnace in Horizontal Left Orientation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 535-878 Printed in U.S.A. Form 58DXT-2SI Pg 1 4-97 Replaces: New Tab 6a 8a DOOR CLIP INSTALLATION INSTRUCTIONS FOR HORIZONTAL APPLICATIONS Assembly Part No. 324097-701 1997 Carrier Corporation 330j602 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 535-878 Printed in U.S.A. Form 58DXT-2SI Pg 2 4-97 Replaces: New Tab 6a 8a