Carrier 58M 98SI Gas Furnace Owners Manual

Product Specification
CategoriesCarrier HVAC Manuals
Document TypeHeating, Ventilating and Air Conditioning Manual Free Download. HAVC Operator's Instruction Manual.
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 4 pages
LanguageEnglish
Product BrandCarrier. Support Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays , Heating, Ventilating and Air Conditioning - HVAC
Document File TypePDF
Publishercorp.carrier.com
Wikipedia's PageCarrier Corporation
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Igniter Bracket Kit Cancels: IIK 340M-40-73 IIK 340M-40-85 4-04 Installation Instructions Part No. 329494­751 NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS Installing and servicing of heating equipment can be hazardous due to gas and electrical components. Only trained personnel should install or service heating equipment.

Untrained personnel can perform basic maintenance functions such as cleaning coils or cleaning and replacing filters. All other operations should be performed by trained service personnel. When working on heating equipment, observe precautions in the literature, on tags, and on labels attached to the unit. Follow all safety codes. Wear safety glasses and work gloves. Have a fire extinguisher available Recognize safety information. This is the safety-alert symbol When you see this symbol on the furnace and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words, DANGER, WARNING, CAUTION and NOTE. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard whichcould result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. INSTALLATION Step 1–Remove Complete Burner Box Assembly NOTE: Instructions written for upflow orientation. Some modifications may be required for other orientations. See Fig. 1 for furnace component locations. See Fig. 3 for exploded view of heat system components. 1. Turn off gas and electrical supplies to furnace. 2. Remove furnace door. 3. Disconnect combustion-air intake pipe from intake housing. Move pipe out of furnace casing. 4. Disconnect gas supply pipe from gas valve using backup wrench. 5. Remove 2 screws securing top filler panel and rotate panel upwards to remove. 6. Remove flame sensor leads, hot surface igniter, gas valve, auxilary and main limit switch wires and lay harness on blower shelf. Identify wires for proper reconnection. 7. Remove 2 screws securing black plastic air intake housing to burner enclosure, and rotate intake housing away from burner enclosure for removal. 8. Remove pressure switch tube from intake housing. 9. Remove screws securing burner box cover with sight glass. 10. Remove screws securing gas manifold to burner box removing from burner box. 11. Remove screws in burner box flange to remove burner box and gasket assembly from center cell panel. ELECTRICAL SHOCK AND FIRE HAZARD Failure to follow this warning could result in personal injury or death. Turn off gas and electrical supplies to unit before beginning any installation or modification. Follow operating instructions on label attached to furnace. Step 2–Install Igniter 1. Remove original igniter bracket with igniter. 2. Modify new igniter bracket (supplied in this kit). Bend 3/8 inch angled tab flat to match horizontal surface of bracket that mounts flush to the burner box. (See Fig. 4) 3. Install igniter in bracket passing igniter molex plug and wire leads through bracket and gasket. Rest igniter in bracket. 4. Attach igniter to bracket using one #8 x 3/4 LG screw. NOTE: Do not overtighten screw or ceramic may break. 5. Insert igniter assembly into burner box igniter hole. INTRODUCTION This instruction covers installation of the igniter bracket kit Part No. 329494­751 in 40­in. tall, condensing gas furnaces. DESCRIPTION AND USAGE Use this igniter bracket kit when replacement of factory-installed igniter bracket is required. This igniter bracket kit contains the following items: INSTALLATION TIP: Do not allow igniter to hit or bump objects while installing. Do not touch or handle igniter element. Igniter may develop micro-cracks and cause it’s life to be shorter. 6. Mark screw holes at both ends of igniter bracket. 7. Remove igniter assembly and drill screw holes with 1/8 in. drill bit. 8. Reinstall igniter assembly into burner box and attach with two #8 x 3/4 LG sheet metal screws.

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website