Carrier 58MVP 10SI Gas Furnace Owners Manual

Product Specification
CategoriesCarrier HVAC Manuals
Document TypeHeating, Ventilating and Air Conditioning Manual Free Download. HAVC Operator's Instruction Manual.
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 48 pages
LanguageEnglish
Product BrandCarrier. Support Phone Number: In North America, please call 1-800-CARRIER for immediate customer assistance from 8:00a -5:00p (EST) weekdays , Heating, Ventilating and Air Conditioning - HVAC
Document File TypePDF
Publishercorp.carrier.com
Wikipedia's PageCarrier Corporation
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

58MVP 4-Way Multipoise Direct-Vent Variable-Capacity Condensing Gas Furnace Visit www.carrier.com Installation, Start-Up, and Operating Instructi0ns For Sizes 040–120, Series 140 and 150 AIRFLOW NOTE: Read the entire instruction manual before starting the installation. UPFLOW A93040 HORIZONTAL LEFT DOWNFLOW AIRFLOW HORIZONTAL RIGHT AIRFLOW This symbol indicates a change since the last issue. Index Page DIMENSIONAL DRAWING 2 SAFETY CONSIDERATIONS .3 Clearances to Combustibles 3 ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS 3-4 INTRODUCTION 4 APPLICATIONS 4-11 General 4 Upflow Applications 4-7 Downflow Applications .7-8 Horizontal Left (Supply-Air Discharge) Applications .8-9 Horizontal Right (Supply-Air Discharge) Applications .9-11 LOCATION 11-13 General .11-12 Low-Fire Only Installation 12-13 Furnace Location Relative to Cooling Equipment 13 Hazardous Locations .13 INSTALLATION 13-15 Leveling Legs (If Desired) .13 Installation In Upflow or Downflow Applications 13-15 Installation In Horizontal Applications 15 AIR DUCTS 15-18 General Requirements .15-16 Ductwork Acoustical Treatment .16 Supply Air Connections 16 Return Air connections .16 Filter Arrangement 16 Bottom Closure Panel 16-18 Gas Piping .18 ELECTRICAL CONNECTIONS .18-20 115-v Wiring 18-19 24-v Wiring 19-20 Accessories 20 DIRECT VENTING .20-31 Removal of Existing Furnaces from Common Vent Systems 20-22 Combustion-Air and Vent Piping .22-28 Concentric Vent and Combustion-Air Termination Kit Installation 28-31 Multiventing and Vent Terminations .31 CONDENSATE DRAIN 31-33 General 31 Application 31 Condensate Drain Protection .31-33 AIRFLOW Fig.

1–Multipoise Orientations A93041 ama CERTIFIED As an ENERGY STARĀ® Partner, Carrier Corporation has determined that this product meets the ENERGY STARĀ® guidelines for energy efficiency. REGISTERED QUALITY SYSTEM SEQUENCE OF OPERATION 33-36 Self-Test Mode 33 Heating Mode 33-34 Heating Mode–Two Stage 34 Emergency Heat Mode .34 Cooling Mode .34 Heat Pump Mode .34-35 Continuous Fan Mode .35-36 Component Test 36 Bypass Humidifier Mode 36 Dehumidification Mode 36 Zone Mode 36 START-UP PROCEDURES 36-45 General .36-37 Select Setup Switch Positions 37 Prime Condensate Trap With Water .37-38 Purge Gas Lines 38 Adjustments .38-45 Set Gas Input Rate .38-44 Set Temperature Rise 44 Set Thermostat Heat Anticipator 45 CHECK SAFETY CONTROLS 45 Check Primary Limit Control .45 Check Pressure Switch .45 CHECKLIST .45-46 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 535-786 Printed in U.S.A. Form 58MVP-10SI Pg 1 10-00 Replaces: 58MVP-9SI Tab 6a 8a 26 15/16 ” 26 1/4 ” 24 1/2 ” 22 5/16 ” 13/16 ” 28 1/2 ” 26 15/16 ” AIRFLOW A D OUTLET CONDENSATE DRAIN TRAP LOCATION (DOWNFLOW & HORIZONTAL RIGHT) OR ALTERNATE 1 /2-IN. DIA GAS CONN

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website