Mitsubishi Mr Slim SUZ KA25 KA35 KA50 KA60 KA71VA Air Conditioner Installation Manual

Product Specification
CategoriesMitsubishi HVAC Manuals
Document TypeHeating, Ventilating and Air Conditioning Manual, HVAC.
Tags
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 8 pages
LanguageEnglish
Product BrandHeating, Ventilating and Air Conditioning Manual, Mitsubishi Electric US, Inc. Americas Corporate Office Phone: 714-220-2500; Application support or for technical information regarding applications for Mr. Slim, Toll-free: 1-800-433-4822
Document File TypePDF
Publishermehvac.com
Wikipedia's PageMitsubishi Electric
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Air-Conditioners SUZ- KA25, KA35, KA50, KA60, KA71VA INSTALLATION MANUAL FOR INSTALLER For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing the air-conditioner unit. English Contents The following should always be observed for safety Selecting the installation location . Installation diagram Drain piping for outdoor unit .

Refrigerant piping work Electrical work Maintenance The following should always be observed for safety Please provide an exclusive circuit for the air conditioner and do not connect other electrical appliances to it. · Be sure to read “The following should always be observed for safety ” before installing the air conditioner. · Be sure to observe the cautions specified here as they include important items related to safety. · The indications and meanings are as follows. Warning: Could lead to death, serious injury, etc. Warning: · Do not install it by yourself (customer). Incomplete installation could cause injury due to fire, electric shock, the unit falling or leakage of water. Consult the dealer from whom you purchased the unit or special installer. · Install the unit securely in a place which can bear the weight of the unit. When installed in an insufficient strong place, the unit could fall causing injured. · Use the specified wires to connect the indoor and outdoor units securely and attach the wires firmly to the terminal board connecting sections so the stress of the wires is not applied to the sections. Incomplete connecting and fixing could cause fire. · Do not use intermediate connection of the power cord or the extension cord and do not connect many devices to one AC outlet. It could cause a fire or an electric shock due to defective contact, defective insulation, exceeding the permissible current, etc. · Check that the refrigerant gas does not leak after installation has completed. · Caution: Could lead to serious injury in particular environments when operated incorrectly. · After reading this manual, be sure to keep it together with the instruction manual in a handy place on the customer’s site. : Indicates a part which must be grounded. Warning: Carefully read the labels affixed to the main unit. · Perform the installation securely referring to the installation manual. Incomplete installation could cause a personal injury due to fire, electric shock, the unit falling or leakage of water. · Perform electrical work according to the installation manual and be sure to use an exclusive circuit. If the capacity of the power circuit is insufficient or there is incomplete electrical work, it could result in a fire or an electric shock. · Attach the electrical part cover to the indoor unit and the service panel to the outdoor unit securely. If the electrical part cover in the indoor unit and/or the service panel in the outdoor unit are not attached securely, it could result in a fire or an electric shock due to dust, water, etc. · Be sure to use the part provided or specified parts for the installation work. The use of defective parts could cause an injury or leakage of water due to a fire, an electric shock, the unit falling, etc. · Ventilate the room if refrigerant leaks during operation. If the refrigerant comes in contact with a flame, poisonous gases will be released. Caution: · Perform grounding. Do not connect the ground wire to a gas pipe, water pipe arrester or telephone ground wire. Defective grounding could cause an electric shock.

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website